🎉 Release of add-on Network UPS Tools 0.7.0

This commit is contained in:
Community Hass.io Add-ons Bot 2021-05-04 08:37:45 +00:00
parent 503bd20bc6
commit 672e8d2dbe
5 changed files with 39 additions and 20 deletions

View file

@ -858,10 +858,10 @@ SOFTWARE.
[matrix-armhf-shield]: https://img.shields.io/badge/armhf-yes-green.svg [matrix-armhf-shield]: https://img.shields.io/badge/armhf-yes-green.svg
[matrix-armv7-shield]: https://img.shields.io/badge/armv7-yes-green.svg [matrix-armv7-shield]: https://img.shields.io/badge/armv7-yes-green.svg
[matrix-i386-shield]: https://img.shields.io/badge/i386-yes-green.svg [matrix-i386-shield]: https://img.shields.io/badge/i386-yes-green.svg
[addon-nut]: https://github.com/hassio-addons/addon-nut/tree/v0.6.2 [addon-nut]: https://github.com/hassio-addons/addon-nut/tree/v0.7.0
[addon-doc-nut]: https://github.com/hassio-addons/addon-nut/blob/v0.6.2/README.md [addon-doc-nut]: https://github.com/hassio-addons/addon-nut/blob/v0.7.0/README.md
[nut-issue]: https://github.com/hassio-addons/addon-nut/issues [nut-issue]: https://github.com/hassio-addons/addon-nut/issues
[nut-version-shield]: https://img.shields.io/badge/version-v0.6.2-blue.svg [nut-version-shield]: https://img.shields.io/badge/version-v0.7.0-blue.svg
[nut-aarch64-shield]: https://img.shields.io/badge/aarch64-yes-green.svg [nut-aarch64-shield]: https://img.shields.io/badge/aarch64-yes-green.svg
[nut-amd64-shield]: https://img.shields.io/badge/amd64-yes-green.svg [nut-amd64-shield]: https://img.shields.io/badge/amd64-yes-green.svg
[nut-armhf-shield]: https://img.shields.io/badge/armhf-yes-green.svg [nut-armhf-shield]: https://img.shields.io/badge/armhf-yes-green.svg

View file

@ -1,11 +1,30 @@
## Whats changed ## Whats changed
Adds optional deadtime configuration, to ease stale issues with Cyberpower UPS devices. ## 🧰 Maintenance
## 🚀 Enhancements - Apply updated repository structure & CI workflow @frenck (#128)
- 🔨 Add deadtime configuration option @sinclairpaul (#94)
## 📚 Documentation ## 📚 Documentation
- 🔨 Add deadtime configuration option @sinclairpaul (#94) - 📚 Fix formatting @sinclairpaul (#99)
## ⬆️ Dependency updates
- Bump release-drafter/release-drafter from v5.13.0 to v5.14.0 @dependabot (#101)
- Bump docker/build-push-action from v2.2.2 to v2.3.0 @dependabot (#103)
- Bump actions/stale from v3.0.16 to v3.0.17 @dependabot (#104)
- Bump actions/stale from v3.0.17 to v3.0.18 @dependabot (#107)
- Bump release-drafter/release-drafter from v5.14.0 to v5.15.0 @dependabot (#110)
- Bump frenck/action-addon-linter from v2.0.0 to v2.1 @dependabot (#111)
- Bump ludeeus/action-shellcheck from 1.0.0 to 1.1.0 @dependabot (#112)
- Bump docker/build-push-action from v2.3.0 to v2.4.0 @dependabot (#113)
- Bump docker/setup-buildx-action from v1.1.1 to v1.1.2 @dependabot (#114)
- Bump docker/setup-qemu-action from v1.0.1 to v1.0.2 @dependabot (#115)
- Bump actions/cache from v2.1.4 to v2.1.5 @dependabot (#118)
- Bump brpaz/hadolint-action from v1.3.1 to v1.4.0 @dependabot (#119)
- Bump docker/setup-buildx-action from v1.1.2 to v1.2.0 @dependabot (#120)
- Bump docker/setup-qemu-action from v1.0.2 to v1.1.0 @dependabot (#121)
- Bump docker/login-action from v1.8.0 to v1.9.0 @dependabot (#122)
- Bump docker/setup-buildx-action from v1.2.0 to v1.3.0 @dependabot (#123)
- 🔨 Add nut-xml driver @sinclairpaul (#126)
- ⬆Upgrades add-on base image to v4.2.0 @frenck (#127)

View file

@ -171,7 +171,7 @@ devices:
- product = ".*(Smart|Back)-?UPS.*" - product = ".*(Smart|Back)-?UPS.*"
``` ```
#### Option: `mode` ### Option: `mode`
Recognized values are `netserver` and `netclient`. Recognized values are `netserver` and `netclient`.
@ -180,44 +180,44 @@ Recognized values are `netserver` and `netclient`.
- `netclient`: Only runs `upsmon` to connect to a remote system running as - `netclient`: Only runs `upsmon` to connect to a remote system running as
`netserver`. `netserver`.
#### Option: `shutdown_host` ### Option: `shutdown_host`
When this option is set to `true` on a UPS shutdown command, the host system When this option is set to `true` on a UPS shutdown command, the host system
will be shutdown. When set to `false` only the add-on will be stopped. This is to will be shutdown. When set to `false` only the add-on will be stopped. This is to
allow testing without impact to the system. allow testing without impact to the system.
#### Option: `list_usb_devices` ### Option: `list_usb_devices`
When this option is set to `true`, a list of connected USB devices will be When this option is set to `true`, a list of connected USB devices will be
displayed in the add-on log when the add-on starts up. This option can be used displayed in the add-on log when the add-on starts up. This option can be used
to help identify different UPS devices when multiple UPS devices are connected to help identify different UPS devices when multiple UPS devices are connected
to the system. to the system.
#### Option: `remote_ups_name` ### Option: `remote_ups_name`
When running in `netclient` mode, the name of the remote UPS. When running in `netclient` mode, the name of the remote UPS.
#### Option: `remote_ups_host` ### Option: `remote_ups_host`
When running in `netclient` mode, the host of the remote UPS. When running in `netclient` mode, the host of the remote UPS.
#### Option: `remote_ups_user` ### Option: `remote_ups_user`
When running in `netclient` mode, the user of the remote UPS. When running in `netclient` mode, the user of the remote UPS.
#### Option: `remote_ups_password` ### Option: `remote_ups_password`
When running in `netclient` mode, the password of the remote UPS. When running in `netclient` mode, the password of the remote UPS.
**Note**: _When using the remote option, the user and device options must still **Note**: _When using the remote option, the user and device options must still
be present, however they will have no effect_ be present, however they will have no effect_
#### Option: `upsd_maxage` ### Option: `upsd_maxage`
Allows setting the MAXAGE value in upsd.conf to increase the timeout for Allows setting the MAXAGE value in upsd.conf to increase the timeout for
specific drivers, should not be changed for the majority of users. specific drivers, should not be changed for the majority of users.
#### Option: `upsmon_deadtime` ### Option: `upsmon_deadtime`
Allows setting the DEADTIME value in upsmon.conf to adjust the stale time for Allows setting the DEADTIME value in upsmon.conf to adjust the stale time for
the monitor process, should not be changed for the majority of users. the monitor process, should not be changed for the majority of users.

View file

@ -58,5 +58,5 @@ If you are more interested in stable releases of our add-ons:
[nut-features]: https://networkupstools.org/features.html [nut-features]: https://networkupstools.org/features.html
[nut-ha-docs]: https://www.home-assistant.io/integrations/nut/ [nut-ha-docs]: https://www.home-assistant.io/integrations/nut/
[project-stage-shield]: https://img.shields.io/badge/project%20stage-experimental-yellow.svg [project-stage-shield]: https://img.shields.io/badge/project%20stage-experimental-yellow.svg
[release-shield]: https://img.shields.io/badge/version-v0.6.2-blue.svg [release-shield]: https://img.shields.io/badge/version-v0.7.0-blue.svg
[release]: https://github.com/hassio-addons/addon-nut/tree/v0.6.2 [release]: https://github.com/hassio-addons/addon-nut/tree/v0.7.0

View file

@ -1,6 +1,6 @@
{ {
"name": "Network UPS Tools", "name": "Network UPS Tools",
"version": "0.6.2", "version": "0.7.0",
"slug": "nut", "slug": "nut",
"description": "Manage battery backup (UPS) devices", "description": "Manage battery backup (UPS) devices",
"url": "https://github.com/hassio-addons/addon-nut", "url": "https://github.com/hassio-addons/addon-nut",